IMPORTANT NOTE: When purchasing COOLING ONLY HVAC EQUIPMENT, Florida residents must refer to the new Florida Building Code, 8th Edition Section R501.7.2 which became effective on December 31st, 2023. This section can be viewed online here or you may review the letter provided by the Technical Director of the DBPR Florida Building Codes and Standards in the documents section below.
The York YC2E Condenser ar provides the next grade of efficiency in an entry-level model with its 14.3 SEER2 cooling efficiency and high EER2 performance required in southern US climates. Expertly designed and engineered, and rigorously tested, these YC2E air conditioners offer the latest in energy savings and lasting performance for years to come.
Standard Features:
Meets new updated DOE 2023 minimum standards
Durable powder-coating painted finish
Low-sound fan design
Easy installation and serviceability
Aluminum alloy micro-channel coils for maximum efficiency and durability
Extruded louver for extra strength
Streamlined footprint for easier transportation and installation
Removeable fan guard
Swing-out control box
Full access from the top and side
Easier Installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for quicker system installation. The factory installed filter-drier and factory charge for a 15-Ft lineset means less time spent brazing and charging the system. The small base dimension and reduced unit clearances make for easier retrofits.
Accessible Information - QR code on unit provides quick access to technical documents and warranty information.
Durable Finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Champagne colored powdercoat paint further protects external panels.
Quality Coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system providing reliable performance and small unit size.
Rugged Coil Protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design.
Protected Compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high pressure switch. The liquid line filter-drier is factory installed to protect the compressor against moisture and debris.
Reliable Operation - Ball bearing fan motors provide superior performance in extreme temperatures.
Top Discharge - Warm air is blown up, away from the structure and any landscaping and allows compact location on multi-unit applications.ow Maintenance inches Long life, permanently lubricated motor bearings need no annual servicing.
Low Operating Sound Levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 76 dBA or lower. Compatible accessories for further sound reduction are also available.
Better Service Access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance.
Agency Listed inches Safety certified by CSA to UL 1995 / CSA 22.2. Performance certified to ANSI/AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification program.
The York JHET Air Handler line offers the ultimate in application flexibility. This unit may be used for upflow, downflow, horizontal right, or horizontal left applications. These units are D.O.E. compliant to work with new SEER2 models. For added flexibility, an R-22 or R-410A TXV or piston must be field installed to meet the requirement of the desired refrigerant. Some models available with factory installed TXV.
Standard Features:
MaxAlloyTM Coil - Long life aluminum coils built to deliver lasting performance, efficiency and reliability.
Next generation even-flow distributor - designed for balanced refrigerant flow and even coil circuit performance
Next generation high-efficiency blower - delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor
Two-stage operation - provides flexibility in application with single and two-stage outdoor equipment
Next generation insulation and gasket design - reduces thermal transmission paths and reduces sweating
Designed for easy installation and service - casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time
Cabinet air leakage - less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193
Long lasting quality - structural components made of postpowder painted aluminum or galvanized steel to prevent corrosion
Thermoset drain pan - positive slope for drainage to reduce cause for potential mold or contaminants