Toggle Nav
  • Order Online or Call
  • (888) 474 - 9966
  • Mon - Fri 9:00am - 3:00am EST - Se Habla Español
    Sat - Sun 9:00am - 6:00pm EST
My Cart
SHOPPING CART items 0 items

1.5 Ton 14 Seer Bryant Heat Pump System

Model:214DNA018000 - FFMANP019T00
Call for Details

Out of Stock

QTY: - +
  • Free Shipping
  • Low Price Guarantee
Required Options:
1.5 Ton 14 Seer Bryant Heat Pump System is available to buy in increments of 1

Accessories

$73.65

$29.99

$49.95

$29.95

$109.00

$79.00

Model: CT38X50OD-CT34X50OD-6RX048068

$399.00

$229.00

$39.99

$289.00

$36.75

$64.95

$69.95

$72.95

$79.95

Description

The Bryant 214D Heat Pumps with Puron refrigerant provide a collection of features unmatched by any other family of equipment. The 214D has been designed utilizing Bryant™s Puron refrigerant. The environmentally sound refrigerant allows consumers to make a responsible decision in the protection of the earth™s ozone layer. The Legacy heat pump provides low-cost all-season comfort, cooling your home in summer with its up to 15 SEER rating, then reversing when temperatures drop for low-cost electric heat. It adds up to year-round value.


Standard Features:

  • Efficiency: 14 SEER
  • Microtube Technology refrigeration system
  • Indoor air quality accessories available
  • Sound level as low as 69 dBA
  • Sound levels as low as 68 dBA with accessory sound blanket
  • System supports Thermidistat or standard thermostat controls
  • Puron refrigerant-environmentally sound, won™t deplete the ozone layer and low lifetime service cost
  • Scroll compressor
  • Internal pressure relief valve
  • Internal thermal overload
  • High pressure switch
  • Loss of charge switch
  • Filter drier
  • Balanced refrigeration system for maximum reliability
  • DuraGuardt protection package
  • Solid, durable sheet metal construction
  • Dense wire coil guard
  • Baked-on powder paint
  • Long line up to 250 feet, 76.20 m, total equivalent length, up to 200 feet, 60.96 m, condenser above evaporator, or up to 80 ft24.38 m, evaporator above condenser
  • Low ambient, down to -20F/-28.9C, with accessory kit

 

The Bryant FFMA Air Handler is primarily designed for apartment applications as an upflow only indoor fan coil for split-system heat pumps for use with Puron refrigerant . Accessory field-installed electric heat kits are available in 5, 7.5 or 10 kW sizes. The 018, 024, 030, and 036 size units use a piston refrigerant metering device. The 019, 025, 031 and 037 size units come equipped with a TXV. All unit sizes are factory-configured for Puron refrigerant. However, they can be used for R-22 applications with the addition of an accessory R-22 TXV kit. The FFMA 018, 024, 030, and 036 sizes use a 3-speed PSC motor. The FFMA 019, 025, 031, and 037 sizes use a 5-speed multi-tap ECM motor for efficiency. Motors are suspended at three points on rubber grommets for quieter operation. Refrigerant lines and thermostat low voltage connections are made through the top while the high voltage connections are made from either the right, left or top side of the fan coil. Sweat-type refrigerant connections on both liquid and vapor lines make for swift, low-cost installation. All service access to the unit is conveniently located in the front.


Standard Features:

  • Low voltage connection
  • Breaker switch comes with accessory electric heater only
  • Front return shown with grille removed. Units may also be installed as bottom return.
  • Liquid line connection copper
  • Vapor line connection copper
  • High voltage connection 7/8 inches, 22 mm diameter knock outs,both sides of unit
  • Fresh air intakes, 3.4 inches, 85.8 mm diameter opening with plastic cap
  • Primary drain connection 3/4 inches, 19 mm female pipe thread -fpt-
  • Auxiliary drain connection 3/4 inches, 19 mm female pipe thread -fpt-
  • All units are vertical upflow only.


Cabinet Features:

  • The cabinet sizes allow units to fit between standard stud spacings
  • No return-air duct work is required if the application provides for return air in the front of the cabinet through a louvered closet door or optional louvered wall panel.
  • This unit is field convertible to bottom return without the need for an additional accessory kit.
  • The cabinet exterior is made of galvanized sheet metal.
  • The cabinet is fully insulated to meet applications in conditioned space.
  • This unit is not approved for installation in unconditioned spaces.
  • Primary and secondary drain connections exit from the bottom or either side of the cabinet.
  • Fresh air intake holes measuring 3.4 inches, 35mm are located on each side of the unit cabinet and come capped from the factory.

 

Product Specification

Model Number(s) 214DNA018000 - FFMANP019000
Brand Bryant
Type Heat Pump
Ton 1.5 Ton
SEER 14
Cooling Btu 17,800
Cooling Stage(s) 1
Compressor Stage Single
Voltage 208/230V
Electrical Phase(s) 1-Phase
Decibel Level (dB) 69
Blower Multi-Speed
Maximum CFM 600
Refrigerant Type R-410A
Suction Valve Size (Inches) 3/4
Liquid Valve Size (Inches) 3/8
Total Shipping Weight (lbs.) 254
Outdoor Unit Height (Inches) 23 1/8
Outdoor Unit Width (Inches) 35 1/4
Outdoor Unit Depth (Inches) 23 1/8
Indoor Unit Height (Inches) 20 1/2
Indoor Unit Width (Inches) 36 1/2
Indoor Unit Depth (Inches) 17 2/5
Parts Warranty (Years) 10
Compressor Warranty (Years) 10
UPC # 646341708313