The Rheem 14.5 Seer Value Series Condensing Unit
Standard Features:
Painted louvered steel cabinet
Easily accessible control box
Condenser coils constructed with copper tubing and enhanced aluminum fins
Grille/Motor mount for quiet fan operation
Filter Drier (shipped – not installed)
Applications:
Outdoor condensing unit designed for ground level or rooftop installations.
These units offer comfort and dependability for single, multi-family and light commercial applications.
LIMITED WARRANTY:
Conditional Compressor - Ten (10) Years
Parts - Five (5) Years
The Rheem RHLL Series Air Handler
Standard Features:
RHLA/RHLL Series feature GE’s new X-13 motor which provides enhanced SEER performance with most Rheem outdoor units.
11/2 ton [5.3 kW] through 5 ton [17.6 kW] models are between 421/2 to 551/2 inches [1080 to 1410 mm] tall and 22 inches [559 mm] deep.
Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
Factory-installed high efficiency indoor coil.
All models meet or exceed 330 to 400 CFM [156 to 189 L/s] per ton at .3 inches [.7 kPa] of external static pressure.
Enhanced airflow up to .7" external static pressure.
Sturdy construction with 1.0 inch [.24 kPa] of reinforced foil faced jacket insulation for excellent thermal and sound insulation.
Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet UL and cUL requirements for service disconnect
Engineering Features of the RHLA/RHLL/RHSA/RHSL Series
The most compact unit design available, all standard heat air handler models only 421/2 to 551/2 inches [1079 to 1409 mm] high.
Attractive pre-painted cabinet exterior.
Rugged wall steel cabinet construction, designed for added strength and versatility.
1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance.
Four leg blower motor mount.
Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience.
Traditional open wire element design for heat applications.
Field convertible for vertical downflow, horizontal left hand or right hand air supply.
3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors.
Indoor coil design provides low air side pressure drop, high performance and extremely compact size.
Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil.
Coils are constructed of aluminum fins bonded to internally grooved copper tubing.
Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils.
Supply duct flanges provided as standard on air handler cabinet.
Provisions for field electrical, connections available from either side or top of the air handler cabinet.
Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet.
Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [51 mm] for 11/2 inch [38 mm] conduit.
Front refrigerant and drain connections. |